8 connection in ari-premio (description), 8 connection in ari-premio (description) -14 – ARI Armaturen ES11 EN User Manual
Page 14

Page 2-14
Rev. 0040601000 1014
Operating and installation instructions
Electronic positioner ES11
5.8 Connection in ARI-PREMIO (description)
Also refer to ARI-PREMIO operating instructions
Power input for connection in ARI-PREMIO
The voltage supply is connected to terminals N and L in accordance with type identification
plate.
Actuating signal input for connection in ARI-PREMIO
ATTENTION !
Only one actuating signal input may be connected at any one time.
The actuating signal input ...20 mA is connected to terminals Y
I
and
.
The actuating signal input ...10 V is connected to terminals Y
U
and
.
Potentiometer input for connection in ARI-PREMIO
ATTENTION !
When installing the potentiometer, observe the operating instructions for the
electrical linear actuator ARI-PREMIO.
Plug connector R
A
, R
B
, R
C
from potentiometer cable into ES11 and connector 25, 26, 27
into ARI-PREMIO pin block.
Three-step actuating signal output for connection in ARI-PREMIO
Plug connector N L
L of electronic positioner ES11 cable into pin block 1, 11, 14 of
ARI-PREMIO.