Red Lion RLY7 User Manual
General description, Safety summary, Specifications
4.84
(123)
U
(T1)
3.54 (90)
.91 (23.1)
1.73 (43.9)
(T2)
V
W
(T3)
.14 (3.5)
2.95
(75)
(L1)
R
3.15
(80)
INPUT
VDC
RED LION CONTROLS
YORK, PA.
(L2)
S
+
4-32
-
(L3)
T
3.43
(87)
MODEL: RLY7
25 AMP, AT 24-660 VAC
PART: RLY70000
M244
8
3 PHASE SOLID STATE RELAY
INTEGRATED HEAT SINK
OPTICALLY ISOLATED
SOLID STATE SWITCHING
25 A THREE PHASE OUTPUT RATING
24 TO 660 VAC SWITCHING
4 TO 32 VDC CONTROL SIGNAL
ZERO VOLTAGE TURN-ON
MOUNTS ON DIN RAIL OR DIRECTLY TO PANEL
4000 VOLT ISOLATION
BUILT-IN SNUBBER
LED “ON” INDICATOR
CAGE CLAMP TERMINATIONS
GENERAL DESCRIPTION
The RLY7 is a three phase solid state relay that switches load currents up to
25 A. The unit features a zero voltage turn-on detector to minimize radiated RFI
when switching. An internal snubber guards against false triggering of the
output related to high dv/dt applications. A low level DC control signal of 4 to
32 VDC is all that is needed for the switching operation. This unit, highlighted
by the inverse-parallel SCR output, provides a greatly increased operational life
over a mechanical relay by avoiding the usual relay contact problems such as:
arcing, bouncing, and mechanical failure.
The RLY7 can be directly controlled by logic/SSR drive output or sourcing
output of Red Lion Controls products.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or other actuators
not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.
SPECIFICATIONS
OUTPUT SPECIFICATIONS
1. Operating Voltage Range: 24 to 660 VAC
2. Operating Frequency Range: 47 to 63 Hz
3. Maximum Continuous Load Current: 25 Amps (3 pole), 35 Amps (2 pole)
(See Safe Operating Conditions)
5. Min. Load Current: 100 mA
6. Leakage Current @ V
OUT
(Max.): 10 mA
7. Peak Blocking Voltage: 1400 VAC
8. Voltage Drop @ I
OUT
: 3 VAC
9. I
2
T Fusing: 1350 A
2
sec
(For Fusing Purposes, T = 8.3 msec.)
10. Dv/Dt @ V
OUT
(Max.): 1000 V/µsec
MODEL RLY7 - THREE PHASE DIN RAIL MOUNT SOLID STATE RELAY
DIMENSIONS In inches (mm)
UL Recognized Component,
File #E191578
TOP VIEW
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
Bulletin No. RLY7-E
Drawing No. LP0472
Released 03/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net