background image

4

WIRING

WIRING CONNECTIONS

All conductors should meet voltage and

current ratings for each terminal. Also,
cabling should conform to appropriate
standards of good installation, local codes
and regulations. When wiring the module,
use the numbers on the label to identify the
position number with the proper function.
Strip the wire, leaving approximately 1/4"
(6 mm) of bare wire exposed. Insert the
wire into the terminal, and tighten.

1

7

13

Terminals 13 to 18

Terminals 7 to 12

Terminals 1 to 6

INPUT CONNECTIONS

6

3

-TC

+TC

-TC

+TC

N/C

2

+TC

-TC

1

1

-TC

+TC

-TC

3

4

5

2

8

7

10

9

11

+TC

-TC

4

+TC

-TC

-TC

5

14

13

16

15

17

7

8

N/C

+TC

6

12

+TC

18

+

WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOW TO BE
NON-HAZARDOUS.

INPUT AND OUTPUT (I/O) WIRING MUST BE IN
ACCORDANCE WITH CLASS I, DIV. 2 WIRING METHODS
AND IN ACCORDANCE WITH THE AUTHORITY HAVING
JURISDICTION.

LEDS

STS – STATUS LED

The Status LED is a dual color LED that provides information regarding the

state of the module. This includes indication of the various stages of the start-up
routine (power-up), as well as any errors that may occur.

Startup Routine

FIRMWARE UPGRADE

The module's firmware is stored in flash memory so that software/hardware

conflicts are avoided, and so that software features may be added in the future.

During a download, Crimson compares its own library of firmware files with

those stored in the Master module. If they do not match, Crimson will download
the necessary files. The Master then checks to make sure that the I/O modules
contain the same firmware. If they contain a different revision, the Master will
automatically copy those files into the module's flash memory. During this
process, the module LEDs will flash rapidly, starting with the top row, and
progressing through the remaining rows until the process is complete.

Error States

ALM – ALARM LED

The Alarm LED indicates the presence of an input fault condition. When one

or more Input Fault Alarm bits is high, the LED turns on. The alarms may be
disabled for unused inputs.

CONFIGURATION

Programming is done via Crimson

®

software, a Windows

®

compatible

configuration interface. Please see the Crimson manual for more information.

Rapidly Flashing Red

Module is currently running the boot loader and/
or being flash upgraded by Crimson. This occurs
for four seconds during a power up.

Steady Red

Module switching to configuration.

Green

Module performing normally.

Module is controlling properly, but has lost
communication with the Master.

Green/Pulsing Red

Module not controlling, and not communicating.

Solid Red

Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839

Red Lion Controls

China

Unit 101, XinAn Plaza

Building 13, No.99 Tianzhou Road

ShangHai, P.R. China 200223

Tel +86 21 6113-3688

Fax +86 21 6113-3683

Red Lion Controls

Europe

Printerweg 10

NL - 3821 AD Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Red Lion Controls

India

54, Vishvas Tenement

GST Road, New Ranip,

Ahmedabad-382480 Gujarat, India

Tel +91 987 954 0503

Fax +91 79 275 31 350

This manual is related to the following products: