beautypg.com

State PR6 75 XODS User Manual

Page 20

background image

20

FIGURE 72.

CHART # 4.

*GAL CAP

*BTU’s in 1000’s - NAT./L.P.

A

40

36/36

48 3/4”

124 cm

50

38/38

57 1/2”

146 cm

40

40/40

48 3/4”

124 cm

50

48/44

61”

155 cm

75

55 NAT.

63”

160 cm

*Check the model and rating plate attached to the water heater for
specific model number and other detailed information.

2. Set the vertical 3” (7.6 cm) diameter telescoping flue section in place on

the flue collar. Using a # 22 drill bit, drill two holes (180° apart) and secure
the vertical assembly to the flue collar with the two supplied screws.

FIGURE 73.

3. Slide the 6” (15.2 cm) vent telescoping section apart to reveal the

beads. Fill the beads using the supplied caulking.

FIGURE 74.

4. Apply an ample amount of sealant around the oval flare of the jacket.

FIGURE 75.

5. Place the 6” (15.2 cm) vent section over the 3” (7.6 cm) flue section.

Subtract 3/4” (1.9 cm) from the predetermined “X” dimension. This
determines the length of the 6” (15.2 cm) vent extension. Slide the 6”
(15.2 cm) vent extension apart to this dimension and secure with the
two screws supplied.

FIGURE 76.

6. Form the round end of the 6” (15.2 cm) vent extension to the top of the

jacket and secure with four sheet metal screws.

FIGURE 77.

7. Place the 3” (7.6 cm) elbow on the flue extension. Align the elbow to

the hole previously made in the outside wall. Using the slots in the
elbow, mark the 3” (7.6 cm) diameter end of the flue extension. Using
a # 22 drill bit, drill two holes into the flue extension and secure with
the two provided sheet metal screws.

FIGURE 78.

NOTE: the standard kit includes a 3” (7.6 cm) flue extension
and a 6” (15.2 cm) elbow extension. These parts will not
be used with the horizontal kit.

This manual is related to the following products: