4. First remove the 3” (76 mm) horizontal extension from the elbow. Start-

ing with the long end (with four securing holes), place the 6” (152 mm)
diameter vent elbow over the 3” (76 mm) diameter elbow. Bend the
round end “oval” to fit the flared oval end of the jacket top.

FIGURE 18.

5. Making sure the 6” (152 mm) diameter elbow is centered around the 3”

(76 mm) diameter flue, secure the 6” (152 mm) diameter vent pipe
using four sheet metal screws at the connection of the jacket top.

FIGURE 19 .

6. The standard vent kit includes a 6” (152 mm) diameter extension pipe

which is used when “E” dimension is over 6 1/2” (165 mm).

FIGURE 20.

7. If “E” dimension is less than 6 1/2” (165 mm) move to next step.

If “E” dimension is over 6 1/2” (165 mm), assemble the 6” (152 mm)
diameter extension pipe (crimped end) to the 6” (152 mm) diameter vent
elbow and secure using two sheet metal screws. Apply an ample amount
of sealant around the joint to ensure a good seal.

FIGURE 21.

8. Slide the vent collar (to be installed later) over the 6” (152 mm) vent

elbow.

FIGURE 22.

9. Place the water heater at the opening in the wall, at the predetermined

clearance.

FIGURE 23.

10. Move outdoors with all the remaining vent parts. Using the tube of

sealant supplied, run an ample amount on the inside surface of the
collar assembly that will contact the exterior wall and also fill the
bead on the end of the 6” ((152 mm) diameter vent collar.

FIGURE 24.