beautypg.com

Periodic maintenance (cont’d), Burner cleaning, Burner inspection – State GS6 65 XRRT User Manual

Page 19: Housekeeping

background image

Burner Cleaning

In the event your burner needs cleaning, use the follow-

ing instructions:
If inspection of the burner shows that cleaning is required,

turn the gas control knob clockwise ( ) to the “OFF”

position, depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to

“OFF” unless knob is depressed slightly. DO NOT

FORCE.
Loose deposits on or around the burner can be removed

by carefully using the hose of a vacuum cleaner inserted

through the access door of the water heater. If the burner

needs to be removed for additional cleaning, call the local

gas utility to remove and clean the burner and correct the

problem that required the burner to be cleaned.

Burner Inspection

Periodic Maintenance (cont’d)

19

L.P. Gas Control Valve & Burner
Assembly Replacement Information

B

A

C

D

At least once a year a visual inspection should be made of

the main burner and pilot burner. The drawing is for your

reference.

You should check for sooting which is not normal and

will impair proper combustion.

Housekeeping

Vacuum around base of water heater for dust, dirt, and

lint on a regular basis.

WARNING

If after inspection of the vent system you found sooting

or deterioration, something is wrong. Call the local gas

utility to correct the problem and clean or replace the

flue and venting before resuming operation of the

water heater.

WARNING

PROPANE (L.P.) GAS CONTROL VALVE AND BURNER

ASSEMBLY REPLACEMENT INFORMATION.
For Propane (L.P.) Gas Models Only:
Your water heater is equipped with a Propane (L.P.) gas

control valve and a main burner assembly with left hand

threads for the following fittings and their connections.

(1) The connection between the manifold and the gas

control valve (A to B) are left hand threads.

(2) The connection between the main burner orifice

and the manifold (C to D) are left hand threads.

For ordering these replacement parts, please refer to the

“Repair Parts” section of this manual.

WARNING

INSTALLED IN SUITABLE AREA: To insure sufficient

ventilation and combustion air supply, proper clear-

ances from the water heater must be maintained. See

“Locating the New Water Heater” section. Combustible

materials such as clothing, cleaning materials, or

flammable liquids, etc. must not be placed against or

adjacent to the water heater which can cause a fire.

WARNING

Soot build-up indicates a problem that requires correc-

tion before further use. Turn “OFF” gas to water heater

and leave “OFF” until repairs are made, because failure

to correct the cause of the sooting can result in a fire

causing DEATH, SERIOUS BODILY INJURY, OR PROP-

ERTY DAMAGE.

WARNING

Flood damage to a water heater may not be readily visible or

immediately detectible. However, over a period of time a

flooded water heater will create dangerous conditions which

can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY

DAMAGE. Contact a qualified service technician or contrac-

tor to replace a flooded water heater. Do not attempt to

repair the unit! It must be replaced!