Installation Checklist

BEFORE LIGHTING THE PILOT:

1. Check the gas lines for leaks.

a. Use a soapy water solution. DO NOT test for gas

leaks using a match or open flame.

b. Brush the soapy water solution on all gas pipes,

joints and fittings.

c. Check for bubbling soap. This means you have a

leak. Turn “OFF” gas and make the necessary

repairs.

d. Recheck for leaks.

e. Rinse off soapy solution and wipe dry.

VENT PIPE TO

OUTDOORS

OR CHIMNEY

FLOOR DRAIN

HOT

COLD

DRAIN VALVE

TEMPERATURE-PRESSURE

RELIEF VALVE

UNION

SHUTOFF VALVE

DISCHARGE PIPE

(Do not cap or plug)

MODEL RATING PLATE

DRAFT HOOD

2. Is the new temperature-pressure relief valve properly

installed and piped to an adequate drain? See

“Temperature-Pressure Relief Valve” section.

3. Are the cold and hot water lines connected to the

water heater correctly? See “Water Piping” instructions

in the “Installing the New Water Heater” section.

4. Is the water heater completely filled with water? See

“Filling the Water Heater” instructions in the

“Installing the New Water Heater” section.

5. Will a water leak damage anything? See the “Locating

the New Water Heater” section.

6 . Is there proper clearance between the water heater

and anything that might catch fire? See the “Locating

the New Water Heater” section.

7. Do you have adequate ventilation so that the water

heater will operate properly? See “Combustion Air

and Ventilation” in the “Locating the New Water

Heater” section.

8 . Is the draft hood vent piping properly secured? See

“Venting” instructions in the “Installing the New

Water Heater” section.

9. Is there proper clearance between the vent pipe and

anything that might catch on fire? See “Venting”

instructions in the “Installing the New Water Heater”

section.

10. Is the vent pipe properly sloped and does the vent ter-

minate outdoors? See “Venting” instructions in the

“Installing the New Water Heater” section.

11. Do you need to call your gas company to check the

gas pipe and its hookup?

Installing the New Water Heater (cont’d)

13

WARNING

Contaminants in the gas lines may cause improper opera-

tion of the gas control valve that may result in fire or explo-

sion. Before attaching the gas line be sure that all gas pipe is

clean on the inside. To trap any dirt or foreign material in

the gas supply line, a drip leg (sometimes called a sediment

trap) must be incorporated in the piping. The drip leg must

be readily accessible. Install in accordance with the “Gas

Piping” section. Refer to the current edition of the National

Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54.