beautypg.com

A.R.I. D040C EN User Manual

Maintenance instructions

background image

MAINTENANCE INSTRUCTIONS

COMBINATION AIR VALVE

BARAK, MODEL D-040-C 1”

GENERAL INSTRUCTIONS

- Routine service is an integral part of the standard

procedure for maintenance of a water supply system.

- Recommended routine maintenance– once or twice a year, according to the

quality and type of the fluids in the system.

PROCEDURE

1. Close the service valve under the valve base before servicing.

2. Unscrew and remove the metal shell assembly (1-6) from the base (8) by turning

the metal shell (2) counterclockwise with the aid of a belt wrench.

3. Remove the clamping stem (5) from inside the valve body (1) and carefully

pull out the float (6) with the attached rolling seal (3).

4. Check the soundness of the rolling seal (3) by washing it with water and

examining it. Note: Replace the rolling seal (3) in case it is torn.

5. Wash the body (1) and the float (6) with clean water and examine for damage.

Note: Replace the float (6) if it is damaged.

6. Clean the discharge elbow (4) to remove insects and debris.

7. Return the float (6) with the attached rolling seal (3) to its original position in

the valve body (1) and lock them into place with the clamping stem (5).

8. Return the metal shell assembly (1-6) to the base (8) and close by turning it

clockwise. Note: First make sure the O-ring (7) is seated properly in the base of

the valve (8).

9. Remember to open the service valve after the servicing.

PARTS SPECIFICATION

NO.

DESCRIPTION

MATERIAL

1.

Metal Shell

Cast Iron

2.

Valve Body

Reinforced Nylon

3.

Rolling Seal

E.P.D.M.

4.

Discharge Elbow

Polypropylene

5.

Clamping Stem

Reinforced Nylon

6.

Float

Foamed Polypropylene

7.

O-Ring

BUNA-N

8.

Base

Brass

1
2
3

5

6

7

8

4