Table 6, Provisioning options, Lists t – ADTRAN HDSL2 User Manual
Page 21

HDSL2 for General Distribution Installation and Maintenance Practice
Provisioning
61223HDSL2L2-5B
11
Table 6. Provisioning Options
Provisioning Option
Option Settings
Default Settings
1. DSX-1 Line Build Out
1
0-133 feet, 133-266 feet,
266-399 feet, 399-533 feet,
533-655 feet, EXTERNAL
0 to 133 feet
2. DSX-1/DS1 Line Code
B8ZS, AMI
B8ZS
3. DSX-1/DS1 Framing
SF, ESF, Unframed, Auto
ESF
4. Force Frame Conversion
Disabled, Enabled
Disabled
5. Smartjack Loopback
Disabled, Enabled
Enabled
6. Loopback Time Out
None, 120 Min
120 Minutes
7. Latching Loopback Mode
2
T1 (Disabled), FT1 (Enabled)
T1 (Disabled)
8. DS1 Tx Level
0 dB, –7.5 dB, –15 dB
0 dB
9. Span Power
Enabled, Disabled
Enabled
10. Customer Loss Indicator
3
AIS, Loopback, AIS/CI
AIS/CI
11. Performance Reporting Messages
None, SPRM, NPRM, AUTO (both)
AUTO
12. Loop Attenuation Alarm Threshold
0 (Disabled), 1-99 dB
30 dB
13. SNR Margin Alarm Threshold
0 (Disabled), 1-15 dB
04 dB
14. Remote Provisioning
Disabled, Enabled
Enabled
15. Shelf Alarm
4
Disabled, Enabled
Enabled
2. External is used only for Kentrox shelves. Unit transmits 12-volt p-p to DSX panel.
3. Latching Loopback Mode
• T1 - When optioned for T1 mode, the unit does not respond to DDS Latching Loopback codes.
• FT1 (Fractional T1) - DDS Latching Loopback operation is supported. The H2TU-C units which are in the
HDSL circuit are treated as Identical Tandem Data ports and the HTU-R is treated as a different Tandem
Data port.
Note: When operating in FT1 mode and during periods of T1 loss of signal, LOS, or T1 AIS from the customer
CI, the HDSL system will send in the network direction from the HTU-C a Fractional DS1 idle signal
consisting of a repeating 7E (HEX) byte payload within a framed/unframed T1 signal. In addition,
when optioned for FT1 mode, the setting for Customer Loss Response is ignored.
4. Customer Loss Indicator
• AIS - Send AIS to network upon T1 loss of signal or T1 AIS from customer.
• LPBK - HTU-R initiates a network loopback upon T1 loss of signal or T1 AIS from customer.
• AIS/CI - HTU-R sends customer disconnect indication upon loss of signal, loss of synchronization, or receipt
of T1 AIS from customer.
Note: The CI is generated by transmitting the framing received from the network while overwriting the
payload with a repeating pattern. For applications where the DS1 is Extended Superframe, the data
link is overwritten with a Yellow Alarm that is interrupted once every second by a 100 milli-second
code burst of 7E (HEX).
5. Shelf Alarm is on the DDM+, 3192M, and 3192 Units only.