Electrical wiring installation, Electrical wiring installation -8, Assembly – Alamo Interstater FC-FL-0001 User Manual
Page 92: Assembl y
ASSEMBLY
INTERSTATER 03/09
Assembly Section 3-8
© 2009 Alamo Group Inc.
ASSEMBL
Y
Attach the hydraulic pump assemblies to the pump mount plate with (2) 1/2”x1-1/2” Grade 8 bolts and (2) 1/2”
lockwashers. ASM-FL-0017
Attach pivot plate to pump mount weldment with (2) 1/2”x1-1/2” bolts, (2) 1/2” flatwashers and (2) 1/2” locknuts.
Wrap belt around pulleys, adjust tension and tighten all bolts securely. ASM-FL-0018.
ELECTRICAL WIRING INSTALLATION
To prevent any damage to electrical system during wiring procedures, temporarily remove
the negative lead (ground) from battery terminal. Asm-R-0018
Remove ignition switch access panel or ignition switch if panels are not provided in dash. Identify the “Ignition-
Start” wire and the “Ignition-Accessory” wire. ASM-FL-0019