MAINTENANCE

POSSIBLE TROUBLE

CAUSES

REMEDIES

System will not operate in

Oil supply low.

Check oil level and fill.

either direction.

Oil Filter clogged.

Replace Filter Element.

Oil too heavy.

Use proper viscosity oil.

Drive Coupling broken.

Inspect Coupling for sheared Spline
Spline or Key.

System noisy.

Air in system due to low oil level.

Fill in reservoir to sight glass.

Loose Suction Line.

Tighten Fittings.

Clogged Suction Filter.

Replace Filter Element.

Internal Pump or Motor damage.

Disassemble, inspect, and repair.

Sluggish response to

Air in system.

See Step 1A, 1B, 1C, 2B

acceleration

Internal Pump or Motor wear

Disassemble, inspect, and repair.

or damage.