6

‡

started) and then show the percent-of-charge of the battery being charged and either 6 or

12 (the voltage the charger determined the battery is). If you manually stop the charging

process (by pressing the CHARGE RATE button) before the battery is fully charged the

display will show 2)).

‡Battery % – The digital display shows an estimated charge percentage of the battery

connected to the charger battery clips.

‡Voltage – The digital display shows the voltage at the charger battery clips in DC volts.

NOTE: Once the charger has started charging the battery; if you press the Charge Rate

button once, the output current is shut off and the display with show 2)) and then the

battery voltage. If you press the Charge Rate button again, the current will go back on at

the same setting it was when it was turned off. For example: The charger is charging a

battery at the slow charge rate setting. If you press the Charge Rate button, the output is

turned off. If you press the Charge Rate button again, the output will turn back on at the

slow charge rate setting.

9. OPERATING INSTRUCTIONS

WARNING

This battery charger must be properly assembled in accordance with the

assembly instructions before it is used.
Battery Information

This charger can be used with 6 and 12V batteries with rated capacities of 12 Ah to 111 Ah.
Charging

1. Ensure that all of the charger components are in place and in good working condition,

for example, the plastic boots on the battery clips.

2. Connect the battery following the precautions listed in sections 5 and 6.
3. Connect the AC power following the precautions listed in section 7.
4. Select the appropriate settings for your battery.

IMPORTANT

This charger does not have an ON/OFF switch. ON and OFF are controlled

by plugging in the charger to the AC wall outlet. The charger will not supply current to

the battery clips until a battery is properly connected. The clips will not spark if touched

together.
Startup Defaults: :KHQ¿UVWWXUQHGRQWKHFKDUJHUZLOOGHIDXOWWRWKHIROORZLQJ

startup settings:

‡Battery Type: AGM/GEL
‡Charge Rate: OFF (No charge rate selected)

After 10 minutes, if no charge rate is selected, the charger will automatically start charging

at the following defaults:

‡Charge Current: The lowest charge rate setting available, 3 amps.
‡Charge Voltage: If no battery type is selected, 14.7V (for AGM/GEL); if CA/CA is

selected, 16V; if Desulfation is selected, the charger goes into Desulfation Mode.

Battery Connection Indicator
If the charger does not detect a properly connected battery, the CONNECTED

LED will

not light. Charging will not begin if the CONNECTED

LED is not on.

Automatic Charging Mode

When a charge rate is selected, the charger is set to perform an automatic charge.

When an automatic charge is performed, the charger switches to the maintain mode

automatically after the battery is charged.
Aborted Charge

If charging cannot be completed normally, charging will abort. When charging aborts, the

charger’s output is shut off, all of the LEDs are turned off and the digital display will show

an error code (see Troubleshooting for a list of error codes). In that state, the charger

ignores all buttons. To reset after an aborted charge, unplug the charger.
Desulfation Mode

IMPORTANT

Battery must be removed from the car when using this mode, or damage to

the car’s electrical system may result.