6. Cut two pieces of

self-adhesive flashing

6" wide by the sill

pan width + 3" long.

a. For continuous

slab landings

only, cut out the

inside corner.

b. Adhere the

pieces of

flashing to the

inside corners.

Stretch flashing

as needed to

cover corners

and lay flat.

7. Smooth gaps or

bubbles beneath

self-adhesive flashing

with a J-roller

(remove and replace

if necessary).

8. Seal back corners of

sill pan with sealant.

9. For step-down

landings only, cut

plastic drain screen

to length of sill +

2" and staple 1/2"

below sill edge. The

drain screen provides

a path for air to

dry any incidental

moisture in the

rough opening.

End of Stud-Framed

Wall Instructions, continue with section 6, “INSTALL DOOR.”

FOR RETROFIT INSTALLATIONS

Completely remove the old door unit. Verify rough opening is structurally

sound.

PREPARE BUILDING WRAP

Verify these steps are allowed by the building wrap manufacturer.
1. Trim building wrap flush with the edges of the rough opening.
2. If the door extends

beyond the exterior

plain of the building

and a drip cap is

desired, at the head,

slit building wrap

6" at 45°. Tape

up as shown. We

recommend installing

a drip cap because

this integrates the

building wrap and

drip cap to protect

the structure and

the product from

incidental water.

3. Trim the sides

sufficiently to allow
the nailing fin to be
mounted against the
sheathing.

Note!

The rest of the

steps in this section

only apply to a job site

fabricated sill pan. If

installing a sill pan that

you have purchased, follow manufacturer's instructions for installation

and skip to section 6, “INSTALL DOOR.”
4. Apply spray adhesive/primer to the sill pan and surrounding area.

Follow manufacturer’s instructions for application methods.

5. Cut a piece of self-adhesive flashing the length of the sill and apply

over the sill pan as shown. The bottom of the sill pan should be

completely covered by the self-adhesive flashing. For step down

landings, fold flashing down as shown. For continuous slabs, trim

flush with rough opening.

45˚

6"

Sill pan

width

3"

6"

Discard

(for

continuous

slab only)

Continuous Slab

Landing

Sill pan

width

3"

3"

Step-Down

Landing

Sill pan

width

3"

3"

Note!

This section applies to installations into a buck only. For

installations into a stud-framed wall, begin with section 5, “PREPARE
STUD-FRAMED WALL.”
1. Seal any joint larger than 1/16" in the buck and between the buck

and the concrete/masonry with sealant.

2. Cover the buck and the surrounding concrete/masonry at the head

and jambs (apply over sill pan if installing a job site fabricated sill
pan) with liquid applied flashing per manufacture's instructions as
shown.

END of Buck Instructions, SKIP to section 6, “INSTALL DOOR.”