beautypg.com

Asus Maximus IV Extreme User Manual

Page 101

background image

ASUS Maximus IV Extreme

3-9

Vcore MOS volt. Control [Auto]

Use the <+> and <-> keys to adjust the value.

Configuration options: [Auto] [6V] [6.5V] [7V] [7.5V] [8V] [8.5V] [9V] [9.5V]

[10V] [10.5V]
Load-Line Calibration [Auto]

Load-line is defined by Intel VRM spec and affects CPU voltage. The CPU

working voltage will decrease proportionally to CPU loading. Higher load-line

calibration would get higher voltage and better overclocking performance,

but increase the CPU and VRM thermal. From the Regular to Extreme mode

allows you to adjust the voltage range from 0% to 100% to boost the system

performance.

Configuration options: [Auto] [0%] [25% (Suitable for 3.6G-4.2G)] [High]

[50% (Suitable for 4.2G-4.8G)] [75% (Suitable for 4.8G-5.2G)]

[100% (Suitable for 5.2G-6.0G)]

The actual performance boost may vary depending on your CPU specification.

VCore Switching Freq [Auto]

Switching frequency will affect the VRM transient response and component

thermal. Setting a higher frequency gets faster transient response.
[Auto]

Allows you to enable or disable the Spread Spectrum item.

[Manual] Allows you to manually set the frequency with a 10KHz interval.
VRM Fixed Frequency Mode [xxx]

This item appears only when you set the VCore Switching Freq item to

[Manual] and allows you to set a fixed VRM frequency. Use the <+> and <->

keys to adjust the value. The values range from 250KHz to 1100KHz with a

50KHz interval.
Phase Control [Optimized]

Phase number is the number of working VRM phase. Increasing phase

number under heavy system loading to get more transient and better thermal

performance. Reducing phase number under light system loading to increase

VRM efficiency
[Standard]

Proceeds phase control depending on the CPU

loading.

[Optimized]

Loads the ASUS optimized phase tuning profile.

[Extreme]

Proceeds the full phase mode.

[Manual Adjustment] Allows manual adjustment.

When this item is set to [Extreme], the CPU Voltage is set to [Manual] and the

voltage is set to [1.2V] automatically.