GE 45133 GE Choice Alert Water Leak Sensor User Manual

Page 9

background image

8

9

and the Zone LED indicator will flash twice.
Step 3 - Release all buttons. The Zone has

been erased.

Note: The Zone/Sensor cannot be erased if:
- The Zone has been triggered for an Alert or alarm. The
Sensor/Zone must be reset.
- There is loss of signal from the Sensor to the Control
Center (such as low battery, or Sensor is out of range).
- The system is armed.
The Control Center will sound three beeps to indicate it could
not erase the Zone.

Testing a Sensor or your system
Once all the Sensors have been assigned to Zones

in the Control Center you can now test your system.

Ensure the Control Center can receive the signal

from the intended location of the Sensor before

permanently mounting a Sensor.

Step 1 - To place Control Center in Test mode

unplug AC adapter and remove batteries.
Step - Press and hold the ‘Mute’ button and plug

the AC adapter back into the Control Center. When

all the LED indicators turn on, release the Mute

button. The Control Center is now in Test Mode and

any Sensor can now be tested in any Zone.

Note: The sensor has a LED that flashes to show when the
sensor has triggered and transmitted to the Control Center.

Step - Set the Notification Mode to switch ‘Alert’
position and begin activating Sensors one at a time.
Step 4 - When testing is complete, unplug the AC

adapter, then plug the AC adapter back in and

1 2 3 4

Arm

Zone

Armed Power

1

2

3

4

Alert

Chime

Off

Mute

Learn

Input DC 12V

-

+

Step 1
Press and hold
the Learn button
for three seconds

Step 3
Release the
Zone button
Step 4
Activate the Water
Leak Sensor

Step 2
Select the Zone number