3(b). If mounting into a stud or wood surface, use a
1/8” drill bit, drill holes. Align mounting plate holes to
drilled holes, insert screws and screw in until plate has
secure fit.
Do not over-tighten screws.
Removing the Top cover
from the Mounting Plate
To remove the top cover, locate the snap
latch at the bottom of the plate. Using a small
flat blade-type screwdriver, gently push in on
the latch. The top cover will separate from
the mounting plate.
Attaching the Top Cover
to the Mounting Plate
To secure top cover onto mounting plate, position
cover over mounting plate and gently apply equal
pressure to top cover. It will snap securely in place.
Check all sides to ensure secure fit.
Low Battery Indication
The Panic Button has a low battery notification circuit.
Under normal operation, the battery should last up to
24 months. When the battery reaches a low level, the
LED will begin to flash slowly. It will continue to flash
until battery is replaced or becomes exhausted.
Operating the Panic Button
Press the red Panic Button anytime you want to
activate the alarm siren.
Note: Once activated, the alarm siren cannot be
deactivated from the Panic Button wall plate.
The alarm siren can only be deactivated from
the Control Center, Keychain Remote or Wireless
Keypad.