beautypg.com

Installation preparation, Caution, Warning – GE ZV830SMSS User Manual

Page 4

background image

Installation Preparation

4

ADVANCE PLANNING

‡'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
‡3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
‡8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH)RU

VDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRWH[FHHGIW
HTXLYDOHQWOHQJWKIRUDQ\GXFWFRQILJXUDWLRQV

‡5HIHUWR´'XFW)LWWLQJVµFKDUWRQSDJHWRFRPSXWHWKH

PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKHRXWGRRUV

‡:KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQWDLU

V\VWHPLQDFFRUGDQFHZLWKORFDOEXLOGLQJFRGHUHTXLUHPHQWV

Visit GEAppliances.comIRUDYDLODEOHPDNHXSDLUVROXWLRQV

CAUTION:

7RUHGXFHULVNRIILUHDQGWRSURSHUO\

H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH³GRQRWYHQWH[KDXVW
DLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWRDWWLFVFUDZO
VSDFHVRUJDUDJHV

WARNING:

TO REDUCE THE RISK OF FIRE,

USE ONLY METAL DUCTWORK.

‡,QVWDOODZDOOFDSZLWKGDPSHURUURRIFDSDWWKHH[WHULRU

RSHQLQJ2UGHUWKHZDOORUURRIFDSDQGDQ\WUDQVLWLRQ

needed in advance.

:DOO)UDPLQJIRU$GHTXDWH6XSSRUW

‡7KLVYHQWKRRGLVKHDY\$GHTXDWHVWUXFWXUDOVXSSRUWPXVW

EHSURYLGHGLQDOOW\SHVRILQVWDOODWLRQV7KHKRRGPXVW
EHVHFXUHGWRYHUWLFDOVWXGVLQWKHZDOORUWRDKRUL]RQWDO

support.

• 7KHYHQWKRRGVKRXOGEHRQVLWHEHIRUHILQDOIUDPLQJDQG

ZDOOILQLVKLQJ7KLVZLOOKHOSWRDFFXUDWHO\ORFDWHWKHGXFW
ZRUNDQGHOHFWULFDOVHUYLFH

• ,QVWDOODWLRQZLOOEHHDVLHULIWKHYHQWKRRGLVLQVWDOOHGEHIRUH

WKHFRRNWRSDQGFRXQWHUWRSDUHLQVWDOOHG

ACCESSORY DUCT COVER

7KLVKRRGLVVKLSSHGZLWKDGHFRUDWLYHGXFWFRYHUIRUFHLOLQJ
KHLJKWVRIWR7KH=;GXFWFRYHUDFFHVVRU\LV
DYDLODEOHWRUHDFKFHLOLQJKHLJKWVEHWZHHQDQG7KH
DFFHVVRU\VKRXOGEHRUGHUHGZLWKWKHKRRGDQGEHRQVLWH
EHIRUHLQVWDOODWLRQEHJLQV

POWER SUPPLY

IMPORTANT – (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS

APPLIANCE MUST BE PROPERLY GROUNDED.
5HPRYHKRXVHIXVHRURSHQFLUFXLWEUHDNHUEHIRUHEHJLQQLQJ

installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWKWKLV
DSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRUSUHYDLOLQJORFDO

codes and ordinances.

Electrical supply

7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+]DQG
FRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHGEUDQFKFLUFXLW
DQGSURWHFWHGE\DRUDPSFLUFXLWEUHDNHURUWLPH

delay fuse.
• :LULQJPXVWEHZLUHZLWKJURXQG
• ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH

UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUHSURFHHGLQJ

• 5RXWHKRXVHZLULQJDVFORVHWRWKHLQVWDOODWLRQORFDWLRQDV

SRVVLEOHLQWKHFHLOLQJRUEDFNZDOO5HIHUWRWiring Locations
RQSDJH

• &RQQHFWWKHKRRGZLULQJWRWKHKRXVHZLULQJLQDFFRUGDQFH

with local codes.

Grounding instructions

7KHJURXQGLQJFRQGXFWRUPXVWEHFRQQHFWHGWRDJURXQGHG
PHWDOSHUPDQHQWZLULQJV\VWHPRUDQHTXLSPHQWJURXQGLQJ

terminal or lead on the hood.

WARNING:

The improper connection of the

HTXLSPHQWJURXQGLQJFRQGXFWRUFDQUHVXOWLQDULVNRI
HOHFWULFVKRFN&KHFNZLWKDTXDOLILHGHOHFWULFLDQRUVHUYLFH
UHSUHVHQWDWLYHLI\RXDUHLQGRXEWZKHWKHUWKHDSSOLDQFHLV
SURSHUO\JURXQGHG

CAUTION:

$XWRPDWLFDOO\2SHUDWHG'HYLFH²

7RUHGXFHWKHULVNRILQMXU\GLVFRQQHFWIURPSRZHUVXSSO\
EHIRUHVHUYLFLQJ7KLVXQLWLVHTXLSSHGZLWKDQLQWHJUDO
GLVFRQQHFWLQJVZLWFKORFDWHGLQVLGHWKHEORZHUKRXVLQJ