Miracle steamer, Troubleshooting (continued) – Antunes, AJ MS-150/155 User Manual
Page 21
MIRACLE STEAMER
21
P/N 1010699 Rev. M 12/06
Problem
Possible Cause
Corrective Action
Unit floods overnight and/or
continues to steam even when
in idle mode.
Solenoid Valve is leaking due to
debris trapped inside the plung-
er (MS-250/255).
Attempt to flush the debris out of the valve
by rapidly operating the unit on a number of
“single shot” cycles and then letting it rest. If
the unit still leaks, disassemble the Solenoid
Valve and clean out the plunger. Reassemble
unit and test. If a leak is still present, replace
the Solenoid Valve. Contact your maintenance
person or Authorized Service Agency.
Solenoid Valve is installed incor-
rectly (MS-250/255).
If the Solenoid Valve was replaced, verify that
the “IN” and “OUT” labels on the valve corre-
spond to the water flow.
There is no pre-strainer or filter
on the water line just before the
unit (MS-250/255).
Equipment was supplied with a strainer. If
missing, install strainer.
TROUBLESHOOTING (continued)