MIRACLE STEAMER

13

P/N 1010699 Rev. M 12/06

R EA

DY

Hi-Limit Reset Button

A hi-limit thermostat turns off electrical power to the

steam generator if it overheats. To reset this thermo-

stat, allow approximately 45 minutes for the unit to cool

down, remove the black cap, and then press the black

reset button located on the rear of the unit (Figure 7).

If the unit requires continuous resetting, contact your

Roundup authorized service agency.

Figure 7. Hi-Limit Reset Button (MS-150 shown)

Fault Codes

When the programming parameters for Minutes/

Seconds/SHO/H2O have been inadvertently changed

below or above their limits, the unit displays the “

ERR

fault code. If this code appears, clear these settings

using the procedure below:
1. Turn the unit off.
2. Press and hold the Program and Start/Stop

buttons simultaneously (for all units except MS-

150/250 with Mfg. number 9100424, 432, 433

& 439) or Up and Down Arrow buttons for MS-

150/250 with Mfg. number 9100424, 432, 433, &

439 only).

3. Turn the unit on while holding the appropriate

buttons. Release the buttons when the unit stops

beeping,

4. The display will now register the cycle time.
NOTE: Repeat these steps if the unit still displays

the ERR fault code.
NOTE: It is recommended that the SHO and H2O

settings be adjusted to the recommended settings

shown in the Programming section of this manual.

Hi-Limit Reset Button

Power Cord

Cap

OPERATION (continued)

Status Indicator LEDs

The Miracle Steamer’s Control Board has 4 Status

Indicator LEDs described below:
Green (Program): When lit, indicates the unit is in

Program mode.
Yellow (Audio): When lit, indicates 10-15 VDC is being

supplied to the audio signal. The audio signal sounds

and the LED lights for approximately 3 seconds.
Red (Heat): When lit, indicates the Control Board is

calling for heat by supplying 10-15 VDC to the Solid

State Relay. When off, indicates that the unit is satis-

fied.
Green (H2O): When lit, indicates that 24 VAC is being

supplied to operate the solenoid valve (MS-250/255) or

water pump (MS-150/155/355).

This LED is only lit for

approximately 1 second.

UP

DOWN

PRGM

START/STOP

POWER

READY

ERR

The “ERR” Fault Code