HP ProLiant DL388e Gen8 Server User Manual
Page 115
![background image](/manuals/398869/115/background.png)
Specifications 115
•
HP 750 W CS Titanium Hot-plug Power Supply (96% efficiency) (on page
•
HP 750 W CS -48 V DC Hot-plug Power Supply (94% efficiency) (on page
•
HP 1200 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) (on page
For detailed power supply specifications, see the QuickSpecs on the HP website
CAUTION:
Check the system and power supply input ratings before powering up the server.
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
Specification
Value
Input requirements
—
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz to 60 Hz
Rated input current
6 A to 3 A
Rated input power
526 W at 100 V AC input
505 W at 200 V AC input
Btu per hour
1794 at 100 V AC input
1725 at 200 V AC input
Power supply output
—
Rated steady-state power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Maximum peak power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
HP 460 W CS Platinum Hot-plug Power Supply (94% efficiency)
Specification
Value
Input requirements
—
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz to 60 Hz
Rated input current
6 A to 3 A AC input
Rated input power
517 W at 100 V AC input
496 W at 200 V AC input
Btu per hour
1764 at 100 V AC input
1736 at 120 V AC input
1694 at 200 V AC input
1692 at 208 V AC input
1689 at 220 V AC input
1687 at 230 V AC input
1686 at 240 V AC input