beautypg.com

HP OneView for Red Hat Enterprise Virtualization User Manual

Page 10

background image

2.

Configure HP Insight Control for RHEV by running the setup script hpicrhev_setup.py. The
setup script is placed in /usr/local/bin and in the path /usr/lib/hpicrhev-x.x.x.x, so it can
be run from any directory. For RHEV 3.2 configurations, you will need the postgres database
password and the RHEV-M credentials you entered when you ran the rhevm-setup script.
With RHEV 3.3 configurations, the password will not be available until you change the default
postgres password.

[root@rhevm ~]# hpicrhev_setup.py

Welcome to HP Insight Control for RHEV.....

Enter Postgres Password:

Creating database....

Enter Username with Domain name for RHEV [admin@internal]:

Password:

Configuring events....

Importing reports....

Configuring snmptrapd....

Backup copy of "snmptrapd.conf" has been renamed to

"snmptrapd-20131118_105135.conf" and placed in

"/etc/snmp/".

Database settings configuration....

Starting HP Insight Control for RHEV services

NOTE:

RHEV-M will prompt the user for a Postgres password if Postgres is configured with

md5.

NOTE:

hpicrhev_setup.py

will ensure the /opt/hp subdirectory has the appropriate

permissions (read/write/execute for owner and read/execute for group and other, i.e.
rwxr-xr-x

). If the subdirectory does not have the correct permissions, the setup script will

ask if you want to change them:

The /opt/hp directory already exists but does not have

appropriate permissions.

HP Insight Control for RHEV requires read/write

permissions to this directory in order to function

properly.

Allow HP Insight Control for RHEV to change permissions

of this directory? [yes/no]:

Answering yes will continue the setup procedure. Answering no will abort the setup.

NOTE:

Entering an incorrect Postgres password will result in the following error message:

Please confirm your database password and ensure that

"md5" authentication method is selected.

NOTE:

If you do not have the RHEV Reports package installed, the Importing reports step

will fail. This is a non-fatal error.

Before HP Insight Control for RHEV can display information about hosts (iLOs/servers, blade
enclosures and Virtual Connect) in your environment, they must first be discovered.

NOTE:

Host credentials are required in order for discovery to succeed.

10