HP OneView for Red Hat Enterprise Virtualization User Manual
Page 10

2.
Configure HP Insight Control for RHEV by running the setup script hpicrhev_setup.py. The
setup script is placed in /usr/local/bin and in the path /usr/lib/hpicrhev-x.x.x.x, so it can
be run from any directory. For RHEV 3.2 configurations, you will need the postgres database
password and the RHEV-M credentials you entered when you ran the rhevm-setup script.
With RHEV 3.3 configurations, the password will not be available until you change the default
postgres password.
[root@rhevm ~]# hpicrhev_setup.py
Welcome to HP Insight Control for RHEV.....
Enter Postgres Password:
Creating database....
Enter Username with Domain name for RHEV [admin@internal]:
Password:
Configuring events....
Importing reports....
Configuring snmptrapd....
Backup copy of "snmptrapd.conf" has been renamed to
"snmptrapd-20131118_105135.conf" and placed in
"/etc/snmp/".
Database settings configuration....
Starting HP Insight Control for RHEV services
NOTE:
RHEV-M will prompt the user for a Postgres password if Postgres is configured with
md5.
NOTE:
hpicrhev_setup.py
will ensure the /opt/hp subdirectory has the appropriate
permissions (read/write/execute for owner and read/execute for group and other, i.e.
rwxr-xr-x
). If the subdirectory does not have the correct permissions, the setup script will
ask if you want to change them:
The /opt/hp directory already exists but does not have
appropriate permissions.
HP Insight Control for RHEV requires read/write
permissions to this directory in order to function
properly.
Allow HP Insight Control for RHEV to change permissions
of this directory? [yes/no]:
Answering yes will continue the setup procedure. Answering no will abort the setup.
NOTE:
Entering an incorrect Postgres password will result in the following error message:
Please confirm your database password and ensure that
"md5" authentication method is selected.
NOTE:
If you do not have the RHEV Reports package installed, the Importing reports step
will fail. This is a non-fatal error.
Before HP Insight Control for RHEV can display information about hosts (iLOs/servers, blade
enclosures and Virtual Connect) in your environment, they must first be discovered.
NOTE:
Host credentials are required in order for discovery to succeed.
10