Hot-plug sas and sata hard drive options – HP ProLiant DL360 G6 Server User Manual
Page 45

Hardware options installation 45
CAUTION:
To avoid damage to the hard drives, memory, and other system components, the air
baffle, drive blanks, and access panel must be installed when the server is powered up.
1.
Power down the server (on page
2.
Extend the server from the rack (on page
3.
Remove the access panel (on page
4.
Remove the BBWC battery pack, if installed ("
" on page
5.
Remove the air baffle (on page
6.
Open the DIMM slot latches.
7.
Install the DIMM.
8.
Install the air baffle (on page
9.
Install the BBWC battery pack, if removed ("
Installing the BBWC battery pack
" on page
10.
Install the access panel (on page
If you are installing DIMMs in mirrored or lock-step configuration, configure this mode in RBSU ("
" on page
For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display LED
combinations (on page
)."
Hot-plug SAS and SATA hard drive options
When adding hard drives to the server, observe the following general guidelines:
•
The system automatically sets all device numbers.
•
If only one hard drive is used, install it in the bay with the lowest device number ("
" on page
•
Hard drives must be SFF types.
•
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.