Nmi jumper, Hp systems insight display leds, Systems insight display leds – HP ProLiant DL360 G6 Server User Manual

Page 13: Hp systems insight, Display leds

background image

Component identification 13

When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all
system configuration settings from both CMOS and NVRAM.

CAUTION:

Clearing CMOS and/or NVRAM deletes configuration information. Be sure to

properly configure the server or data loss could occur.

NMI jumper

The NMI jumper allows administrators to perform a memory dump before performing a hard reset. Crash
dump analysis is an essential part of eliminating reliability problems, such as hangs or crashes in OSs, device

drivers, and applications. Many crashes can freeze a system, requiring you to do a hard reset. Resetting the
system erases any information that would support root cause analysis.
Systems running Microsoft® Windows® experience a blue-screen trap when the OS crashes. When this

happens, Microsoft® recommends that system administrators perform an NMI event by temporarily shorting
the NMI header with a jumper. The NMI event enables a hung system to become responsive again.

HP Systems Insight Display LEDs

The HP Systems Insight Display LEDs represent the system board layout. The display provides status for all

internal LEDs and enables diagnosis with the access panel installed.
To view the LEDs, access the HP Systems Insight Display (on page

20

).

Item

Description

Status

1

Power cap LED

To determine Power cap status, see
"Systems Insight Display LED
combinations (on page

14

)."

2

AMP status

Green = AMP mode enabled
Amber = Failover

Flashing amber = Invalid configuration
Off = AMP mode disabled