Rated steady-state power

460 W at 100V to 120V AC input

460 W at 200V to 240V AC input

Maximum peak power

460 W at 100V to 120V AC input

460 W at 200V to 240V AC input

HP 460W Common Slot Platinum Plus Hot Plug Power Supply
(94% efficiency)

Specification

Value

Input requirements

Rated input voltage

100 to 120 VAC, 200 to

240 VAC

Rated input frequency

50 Hz to 60 Hz

Rated input current

5.2 A at 100 VAC
2.5 A at 200 VAC

Rated input power

517 W at 100V AC input

496 W at 200V AC input

Btus per hour

1764 at 100V AC input
1694 at 200V AC input

Power supply output

Rated steady-state power

460 W at 100V to 120V AC input
460 W at 200V to 240V AC input

Maximum peak power

460 W at 100V to 120V AC input

460 W at 200V to 240V AC input

HP 500W Common Slot 277VAC Hot Plug Power Supply (94%
efficiency)

Specification

Value

Input requirements

Rated input voltage

200 V to 277 V AC

Rated input frequency

50 Hz–60 Hz

Rated input current

3.0 A at 200 V AC
2.0 A at 277 V AC

Rated input power

600 W at 200 V AC input

554 W at 277 V AC input

Btus per hour

1843 at 200 V AC input
1831 at 277 V AC input

Power supply output

Rated steady-state power

500 W at 200 V AC to 277 V AC

input

Maximum peak power

500 W at 200 V AC to 277 V AC
input