beautypg.com

Front panel leds and buttons – HP ProLiant DL360p Gen8 Server User Manual

Page 9

background image

Component identification 9

Item

Description

11

Systems Insight Display

12

USB connector

Front panel LEDs and buttons

8 SFF or 4 LFF

Item

Description

Status

1

UID button/LED

Solid blue = Activated
Flashing blue (1 Hz/cycle per sec) = Remote management or

firmware upgrade in progress

Off = Deactivated

2

Power On/Standby button

and system power LED

Solid green = System on

Flashing green (1 Hz/cycle per sec) = Performing power on sequence

Solid amber = System in standby

Off = No power present*

3

Health LED

Solid green = Normal

Flashing amber = System degraded

Flashing red (1 Hz/cycle per sec) = System critical

Fast-flashing red (4 Hz/cycles per sec) = Power fault**

4

NIC status LED

Solid green = Link to network

Flashing green (1 Hz/cycle per sec) = Network active

Off = No network activity

*Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has

occurred, or the power button cable is disconnected.

**To identify components in a degraded or critical state, see the Systems Insight Display LEDs (on page

15

), check

iLO/BIOS logs, and reference the server troubleshooting guide.