Weight and physical dimensions

nl

Table 12 (page 33)

lists physical properties.

Table 12 16Gb SAN Switch physical dimensions

Measurement

Dimension

27.94 mm (1.1 in)

Height

192.84 mm (7.59 in)

Width

269.46 mm (10.6 in)

Depth

1.49 kg (3.3 lb) without media

Weight

Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in

Table 13 (page 33)

list the acceptable

environment for both operating and nonoperating conditions.

Table 13 Environmental requirements

Acceptable range during non-operation

Acceptable range during operation

Condition

Non-operating -30° to 60°C (-22° to
140°F). Maximum rate of change is
20°C/Hr (36°F/Hr).

10° to 35°C (50° to 95°F) at sea level
with an altitude derating of 1.0°C per
every 305m (1.8°F per every 1000ft)

Ambient
temperature

above sea level to a maximum of 3050m
(10,000ft), no direct sustained sunlight.
Maximum rate of change is 10°C/Hr
(18°F/Hr ). The upper limit may be limited
by the type and number of options
installed. System performance may be
reduced if operating with a fan fault or
above 30°C (86°F).

5% to 95% relative humidity,
non-condensing

10% to 90% relative humidity,
non-condensing

Humidity

0 to 30,000 ft (9144 m) above sea
level

0 to 10,000 ft (3 km) above sea level

Altitude

140 G, 2ms

40 G, 2ms duration

Shock

2.0 G, 5–500 Hz

1 G, 10–500 Hz

Vibration

Supported SFPs

Do not use unsupported SFPs. They may not fit correctly and may void your warranty. Any port
with an unsupported SFP will automatically be disabled by switch firmware, leaving the port
non-operational. See

Supported SFP transceiver options (page 8)

for a list of supported SFPs.

For a complete list of supported devices, see the latest version of the HP SAN Design Reference
Guide
at the HP website:

nl

http://h18000.www1.hp.com/products/storageworks/san/documentation.html

.

Supported HBAs

For a list of HBAs that have been tested and are known to work with the SAN switches, see the
latest version of the HP SAN Design Reference Guide at the HP website:

nl

http://h18000.www1.hp.com/products/storageworks/san/documentation.html

.

Weight and physical dimensions