Troubleshooting, If the storage blade does not power up, Diagnostic questions – HP D2200sb Storage Blade User Manual
Page 27: Is the storage blade operating properly

Troubleshooting 27
Troubleshooting
If the storage blade does not power up
If the storage blade does not start:
1.
Be sure that the storage blade is installed adjacent to the partner server blade.
2.
Use the Onboard Administrator to be sure that sufficient power is available.
3.
Use the Onboard Administrator to verify that sufficient cooling is available.
4.
Restart the partner server blade.
IMPORTANT:
If the system does not restart, proceed to "Diagnostic Questions (on page
)."
5.
Verify that the storage blade front panel health LED changes from flashing amber to solid green.
Diagnostic questions
Is the storage blade operating properly?
Answer
Possible reasons
Possible solutions
No
The storage blade is not installed adjacent to
the partner server blade.
Verify that the storage blade is installed adjacent to
the partner server blade. See "Installation
)."
The partner server blade was not restarted
after the storage blade was installed.
Restart the server blade.
The storage blade is not properly seated in the
device bay.
1
Power down the partner server blade.
2
Reseat the storage blade in the device bay.
3
Restart the server blade.
Insufficient power is available to operate the
storage blade.
•
Remove any unused server blades, storage
blades, or interconnect devices.
•
Verify that the enclosure has sufficient power
supply capacity available to operate all
installed devices.
•
Verify that the enclosure power settings will
enable the storage blade to start.
•
Add power supplies to meet the power
requirement.
Insufficient or improperly located enclosure
cooling fans
•
Verify that a sufficient number of cooling fans
are in the enclosure.
•
Verify that the cooling fans are properly
configured for the devices installed in the
enclosure.
The hard drive drawer was open too long and
triggered overtemperature alerts.
Close the hard drive drawer and wait for normal
operating temperatures to resume. A green health