5 troubleshooting, Problem diagnosis, Problems during installation – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 31
5 Troubleshooting
This chapter discusses the following topics:
• Problem diagnosis
• Problems during installation
• HBA failure
• Cable failure
Problem diagnosis
If the problem is related to the multipath I/O, consult the Insight Management Agents and do one
of the following:
•
For Microsoft operating systems:
• Use the ProLiant Storage Manager or ProLiant Multipath Manager FAQs.
• Use the ProLiant Storage Manager with ProLiant Multipath Manager software, and the DME to
identify the I/O path status.
•
For Linux operating systems, enter the following command to identify HBA status, multipath status,
and I/O block transfer size:
cat /proc/mdstatus
Problems during installation
This section describes how to troubleshoot the most common problems encountered during software
installation.
To troubleshoot the problems encountered during installation, complete the following steps:
1.
In a Microsoft environment, uninstall any previous version of the multipath software first.
2.
Ensure that the firmware is upgraded for all HBAs and both the MSA500 G2 controllers, if
installed.
3.
Ensure that the hardware installation meets the
.
4.
Ensure that the SCSI cabling matches one of the
Supported four-node configurations
5.
Ensure that the HBA is functioning properly. See the appropriate server and HBA documentation.
If the HBA has failed, see
.
6.
Ensure that the SCSI cables are functioning properly. If a SCSI cable fails, see
.
7.
Ensure that you followed operating system-specific instructions:
• If the server has a Red Hat operating system, ensure that the active kernel is edited properly.
• If the server has a Microsoft operating system, ensure that the SCSI cable from the redundant
HBA is disconnected before Smart Array Multipath software installation.
IMPORTANT:
After establishing a redundant configuration and adding a logical volume, use Windows Disk
Manager to detect the new volume.
• If these steps do not solve the installation problem, contact an authorized reseller.
Smart Array Multipath software user guide
31