beautypg.com

Using general properties – HP Integrity NonStop J-Series User Manual

Page 83

background image

“Using the Control Query Defaults tab” (page 87)

“Using the Control Table Statements tab” (page 87)

NOTE:

Some tabs provide tooltips that explain the use of an option or the range of values supported
for a field.

Figure 31 (page 83)

shows a tool tip for one of the fields.

Figure 31 Tooltip in tabs

6.

After configuring the data source properties, click Create.

7.

Refresh the navigation tree pane.

The new data source appears.

8.

To start up the data source, see

“Starting up a data source” (page 90)

.

Terms

data source
navigation tree pane

Using General Properties

Table 22 (page 83)

describes the properties displayed in the General Properties tab.

Table 22 General Properties options

Description

Option

Group

You must assign a unique name for the new data source. The name can
be a maximum of 128 characters (any characters) without leading or

Name

Data Source Name

trailing spaces. Leading or trailing spaces are automatically removed
before the name is sent to the server. Embedded spaces are not removed,
and will return an error.

Specifies that MXCS automatically starts up the initial MXCS servers for
the data source when the MXCS service is started.

Automatic

Start Mode

You must manually start up the MXCS servers for the data source when
the MXCS service is in the Started state. This value is the default.

Manual

Specifies the number of minutes that an MXCS server remains idle before
it stops. This timeout occurs only under the following conditions:

Server Idle Timeout

Performance

The idle server is not connected to a client.

The number of servers exceeds the number of idle servers configured
for the data source.

The system default is 600 seconds. You can assign a value between 1
and 2,147,483,647.

Creating a data source

83

This manual is related to the following products: