HP Integrity NonStop J-Series User Manual
Page 22

Figure 3 Systems Tool dialog
describes the settings in the Systems Tool dialog.
Table 2 Systems Tool settings
Description
Setting
Displays the current state of the system definition (
Connected
or
Disconnected
).
State
Displays the label that identifies this NonStop system. The system name can be up to 32
characters in length, and can consist of letters, numerals, and the underscore character.
System Name
Displays the name of the client data source. If you do not specify a data source, or the
name of the client data source does not match the name of the server data source, the client
Data Source
connects to the default server data source,
TDM_Default_DataSource
. If the client data
source exists, the value of the other fields in the dialog are loaded from the client data
source fields.
Displays the user name.
User Name
Displays the DNS name or IP address of the target NonStop system.
Host
Displays the ODBC/MX server port number.
Port Number
Displays the default catalog to be used when writing a query.
Default Catalog
Displays the default schema to be used when writing a query.
Default Schema
Displays the ODBC/MX driver to be used.
DriverString
CAUTION:
If the default catalog or the default schema is a reserved word in SQL/MX (for
example,
USER
), you must enclose the catalog or schema name in double quotes (
“USER”
).
Otherwise, the connection fails. For information on reserved words, see the SQL/MX Release 3.2
Reference Manual.
describes the Systems Tool options.
22
Managing MXDM system objects