beautypg.com

Installing fbdimms, Hot-plug sas hard drive options – HP ProLiant DL380 G5 Server User Manual

Page 47

background image

Hardware options installation 47

Installing FBDIMMs

CAUTION:

To avoid damage to the hard drives, memory, and other system components, the

air baffle, drive blanks, and access panel must be installed when the server is powered up.

1.

Power down the server (on page

23

).

2.

Extend the server from the rack (on page

23

).

3.

Remove the access panel (on page

24

).

4.

Move the hard drive cables.

5.

Remove the air baffle.

6.

Open the FBDIMM slot latches.

7.

Install the FBDIMM.

8.

Install the air baffle.

9.

Install the access panel (on page

25

).

If you are installing FBDIMMs in an online spare or mirrored configuration, use RBSU ("

HP ROM-Based

Setup Utility

" on page

63

) to configure this feature.

For more information about LEDs and troubleshooting failed FBDIMMs, see "Systems Insight Display LEDs
and internal health LED combinations (on page

15

)."

Hot-plug SAS hard drive options

When adding hard drives to the server, observe the following general guidelines:

The system automatically sets all device numbers.

If only one hard drive is used, install it in the bay with the lowest device number ("

SAS device

numbers

" on page

16

).

Hard drives must be SFF types.

Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.