Component identification 16
Systems Insight Display
LED and color
Internal health
LED color
Status
FBDIMM failure, all slots in
one bank (amber)
Red
One or more FBDIMMs has failed. Test each bank of
FBDIMMs by removing all other FBDIMMs. Isolate the
failed FBDIMM by replacing each FBDIMM in a bank with
a known working FBDIMM.
FBDIMM failure, all slots in
all banks (amber)
Red
One or more FBDIMMs has failed. Test each bank of
FBDIMMs by removing all other FBDIMMs. Isolate the
failed FBDIMM by replacing each FBDIMM in a bank with
a known working FBDIMM.
Online spare memory
(amber)
Amber Bank
X failed over to the online spare memory bank.
Online spare memory
(flashing amber)
Red
Invalid online spare memory configuration.
Online spare memory (green) Green
Online spare memory enabled and not failed.
Mirrored memory (amber) Amber
Bank(s)
X failed over to the mirrored memory bank(s).
Mirrored memory (flashing
amber)
Red
Invalid mirrored memory configuration.
Mirrored memory (green)
Green Mirrored
memory
enabled and not failed.
Overtemperature (amber)
Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Riser interlock (amber)
Red
PCI riser cage is not seated.
Fan (amber)
Amber
One fan is failed or removed.
Red
Two or more fans have failed or are removed.
SAS device numbers