beautypg.com

Sas device numbers – HP ProLiant DL380 G5 Server User Manual

Page 16

background image

Component identification 16

Systems Insight Display
LED and color

Internal health
LED color

Status

FBDIMM failure, all slots in

one bank (amber)

Red

One or more FBDIMMs has failed. Test each bank of

FBDIMMs by removing all other FBDIMMs. Isolate the
failed FBDIMM by replacing each FBDIMM in a bank with

a known working FBDIMM.

FBDIMM failure, all slots in
all banks (amber)

Red

One or more FBDIMMs has failed. Test each bank of
FBDIMMs by removing all other FBDIMMs. Isolate the

failed FBDIMM by replacing each FBDIMM in a bank with

a known working FBDIMM.

Online spare memory
(amber)

Amber Bank

X failed over to the online spare memory bank.

Online spare memory
(flashing amber)

Red

Invalid online spare memory configuration.

Online spare memory (green) Green

Online spare memory enabled and not failed.

Mirrored memory (amber) Amber

Bank(s)

X failed over to the mirrored memory bank(s).

Mirrored memory (flashing
amber)

Red

Invalid mirrored memory configuration.

Mirrored memory (green)

Green Mirrored

memory

enabled and not failed.

Overtemperature (amber)

Amber

The Health Driver has detected a cautionary temperature
level.

Red

The server has detected a hardware critical temperature
level.

Riser interlock (amber)

Red

PCI riser cage is not seated.

Fan (amber)

Amber

One fan is failed or removed.

Red

Two or more fans have failed or are removed.

SAS device numbers