beautypg.com

Using hpacuscripting, Capturing a configuration, Using an input script – HP Linux Server Management Software User Manual

Page 36

background image

Toolkit utilities 36

Using HPACUSCRIPTING

Starting with version 8.28.13.0, ACU Scripting is now a standalone application that is distributed with the
ACU CLI application. In ACU versions prior to 8.28.13.0, the scripting executable was provided with the

ACU GUI component.
Users familiar with the previous versions of ACU Scripting must now install the ACU CLI application to obtain

the scripting executable. The new ACU scripting executable (hpacuscripting) replaces the former executable
(cpqacuxe) in all scripts.
The ACU Scripting application has two scripting modes:

Capture mode for capturing a configuration (on page

36

)

ACU inspects the configuration of all internal and external array controllers connected to the server and
then writes a script file describing this configuration.

Input mode for using an Input script (on page

36

)

ACU reads the array configuration described in a specified script file. See "Creating an ACU script file (on

page

37

)." ACU then applies this configuration to a target system.

NOTE:

For a complete list of all command-line parameters, execute the /? utility.

Capturing a configuration

To capture the configuration of a system, enter the following command at the system command line prompt:

hpacuscripting -c [drive:][path]OUTPUTFILENAME.ext [-internal | -external]

-e [drive:][path]ERRORFILENAME.ext

OUTPUTFILENAME is the name of the capture file, and ext. is the file extension. If you do not specify a name

and location for this file, ACU uses the default name ACUOUTPUT.ini, and places the file in the ACU working

directory.
The -internal and -external switches limit capture to internal or external controllers.
The -e switch information is used only if ACU must generate an error file. By default, ACU names the error

file ERROR.ini and places it in the ACU working directory.

Using an Input script

To use an Input script to configure or reconfigure a system, first locate a suitable ACU script or see "Creating

an ACU script file (on page

37

)."

Then, enter the following command at the system command line prompt:

hpacuscripting -i [drive:][path]FILENAME.ext [-internal | -external] [-reset]

-e [drive:][path]ERRORFILENAME.ext

FILENAME is the name of the ACU input file, and ext is the file extension. If you do not specify the name and

location of this file, ACU searches for ACUINPUT.ini in the ACU working directory.
The -internal and -external switches limit configuration operations to internal or external controllers.
The -reset flag destroys any existing data and overwrites the current configuration with the configuration

specified in the script.