beautypg.com

Supported indication events – HP 2000SA G2-Modular-Smart-Array User Manual

Page 9

background image

This provider supports the following CIM operations:

getClass

enumerateClasses

enumerateClassNames

getInstance

enumerateInstances

enumerateInstaneceNames

associators

associatorNames

references

referenceNames

invokeMethod

The Proxy Provider supports the CIM Alert Indication events listed in

Table 2

, page 9.

Table 2 Supported indication events

Operational status values that trigger alert
indications

Corresponding provider class

Event category

Down, Not Installed, Unknown operational
status

DHS_TopComputerSystem

Controller

Unknown, Missing, Error

DHS_DiskDrive

Hard Disk

Error, Stopped, Unknown operational status

DHS_Fan

Fan

Unknown, Error, Other, Stressed

DHS_PowerSupply

Power Supply

Unknown, Other, Error, NonRecoverable Error

DHS_TemperatureSensor

Temperature Sensor

Unknown, Error

DHS_SuperCap

Battery/SuperCap

Stopped, Unknown operational status

DHS_FCPort

FC Port

Unknown, Stopped

DHS_SASTargetPort

SAS Port

Unknown, Stopped

DHS_ISCSIEthernetPort

iSCSI Port

MSA2000 G2 SMI-S Proxy Provider User Guide

9

This manual is related to the following products: