HP ProLiant BL20p G3 Server Blade User Manual
Page 16

Server Blade Component Identification
Table 1-2: Hot-Plug SCSI Hard Drive LED Status Combinations
(1) Activity
(2) Online (3)
Fault Description
On Off
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
On Flashing
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing Flashing
Flashing
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off
Off
Off
OK to replace the drive online if a predictive failure alert
is received and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, a powered-on controller
is not accessing the drive.
-Or-
The drive is configured as an online spare.
Off
Off
On
OK to replace the drive online.
The drive has failed and has been placed offline.
continued
HP ProLiant BL20p Generation 3 Server Blade User Guide
1-5