Removing a hot-plug sas hard drive, Flash-backed write cache module option – HP ProLiant DL380 G7 Server User Manual
Page 55
Hardware options installation 55
3.
Install the hard drive.
4.
Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations ("
SATA hard drive LED combinations
" on page
).
Removing a hot-plug SAS hard drive
CAUTION:
For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1.
Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations ("
SATA hard drive LED combinations
" on page
).
2.
Back up all server data on the hard drive.
3.
Remove the hard drive.
Flash-backed write cache module option
To install the component:
CAUTION:
Do not use this controller with cache modules designed for other controller models,
because the controller can malfunction and you can lose data. Also, do not transfer this cache
module to a different controller module, because you can lose data.
1.
Back up all data.
2.
Close all applications.
3.
Power down the server (on page