Is the drive enclosure Fault/Service Required LED amber?

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

(blinking)

One of the following errors

occurred:

Hardware-controlled

power-up error

Cache flush error

Cache self-refresh error

Check the event log for specific information regarding

the fault.

Isolate the fault.

Contact an authorized service provider for assistance.

Replace if necessary.

Yes

A fault occurred.
If installing an I/O module

FRU, the module has not gone

online and likely failed its

self-test.

Check the event log for specific information regarding

the fault.

Isolate the fault.

Contact an authorized service provider for assistance.

Replace if necessary.

If installing an I/O module FRU, try removing and

reinstalling the new I/O module, and check the event

log for errors.