beautypg.com

Port status – Axis Communications AXIS Q1755-E User Manual

Page 29

background image

29

AXIS Q1755/-E - Events

Examples:

• Avoid triggering on small objects in the video image by setting the

object size level to high.

• Use several small Motion Detection windows rather than one large window, if triggers on small movements or

objects are desired.

• To reduce the number of triggers if there is a lot of movement during a short period of time, select a high

history

level.

• To only detect flashing light, select low

sensitivity. In other cases, a high sensitivity level is recommended.

Port Status

Under

Events > Port Status there is a list showing the status for the camera’s input and output. This is for the benefit of

Operators who have no access to the System Options section.

Example:

If the Normal state for a push button connected to an input is set to

Open circuit - as long as the button is not

pushed, the state is

inactive. If the button is pushed, the state of the input changes to active.

Object Size

History

Sensitivity

High level

Only very large objects
trigger motion detec-
tion

An object that appears in the region
will trigger the motion detection for
a long period

Ordinary colored objects on ordinary
backgrounds will trigger the motion
detection

Low level

Even very small objects
trigger motion detec-
tion

An object that appears in the region
will trigger motion detection for only
a very short period

Only very bright objects on a dark
background trigger motion detection

Default value Low

High

High

This manual is related to the following products: