Configuring the Virtual Connect domain using the CLI 144
•
Removing a connection that is mapped to Flex-10
•
Assigning a profile to a server that maps Flex-10 connections
•
Unassigning a profile with Flex-10 connections
Flex-10 connection changes that do not require power off
With Virtual Connect Manager v2.10 and higher, it is not necessary to power off a server blade with Flex-10
connections in the following instances:
•
Changing a connection's network:
o
From a single network to another single network
o
From a single network to multiple networks
o
From multiple networks to a single network
•
Modifying the networks or VLAN IDs in a connection with multiple networks
With Virtual Connect Manager v2.30 and higher, it is not necessary to power off a server blade with Flex-10
connections in the following instances:
•
Changing a connection's network:
o
From "unassigned" to a single network
o
From a single network to "unassigned"
o
From "unassigned" to multiple networks
o
From multiple networks to "unassigned"
•
Changing the requested bandwidth
FCoE connection changes that require power off
•
Adding an FCoE connection to an assigned server profile
•
Removing an FCoE connection from an assigned server profile
•
Assigning a profile containing FCoE connections to a server
•
Changing FCoE boot parameters
Restart after OA credential recovery
The state, "profile recovered," is applied to servers that are powered on when VC Manager restarts after an
OA credential recovery. When VC Manager detects a restart after a credential recovery, it rewrites the
profile parameters for any server that is powered on, connects the server to the appropriate Ethernet networks
and FC fabrics, and then puts the server and profile in the "profile recovered" state. The server and profile
remain in the "profile recovered" state until the server is powered down or removed from the enclosure. This
feature eliminates the power cycle requirement for a server to recover.
General requirements for adding FC or FCoE connections
Adding FC and FCoE connections is generally allowed during profile add and edit operations. It is not
allowed in some specific cases. Observe the following general requirements:
•
When a profile is added, the FC/FCoE connections initially displayed are based on the FC/FCoE
module configuration in the domain, respectively. A pair of horizontally adjacent FC/FCoE-capable
modules has two connections.
•
Connections can only be added or removed from the bottom. You can only add or delete connections
at the end of the list.
- 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem