Item
Description
"User-Defined" is specified, EthernetMAC must also be specified. Valid values
include "Factory-Default" and "User-Defined".
EthernetMAC (required
if MACAddressType is
User-Defined)
The user-defined Ethernet MAC address to use for the connection
Examples
->add fcoe-connection MyNewProfile Fabric=SAN_5
Adds a new FCoE connection to a profile
->add fcoe-connection MyNewProfile Fabric=SomeFabric
SpeedType=4Gb
Adds a new FCoE connection and configures the port speed
->add fcoe-connection MyNewProfile
Adds a new FCoE connection and leaves it unassigned
->add fc-connection MyNewProfile Fabric=MyFabric
SpeedType=Custom CustomSpeed=5000
Adds a new FCoE connection and sets a custom speed of 5Gb
->add fcoe-connection MyNewProfile
WWNAddressType=Factory-Default
Adds a new FCoE connection and uses factory-default WWN addresses
->add fcoe-connection MyNewProfile
WWNAddressType=User-Defined
PortWWN=50:06:0B:00:00:C2:62:00
NodeWWN=50:06:0B:00:00:C2:62:01
Adds a new FCoE connection and provides user-defined WWN addresses
->add fcoe-connection MyNewProfile
MACAddressType=Factory-Default
Adds a new FCoE connection and uses factory-default MAC addresses
->add fcoe-connection MyNewProfile
MACAddressType=User-Defined
EthernetMAC=00-17-A4-77-00-00
Adds a new FCoE connection and provides a user-defined MAC address
Item
Description
remove fcoe-connection Remove the last FCoE connection from an existing server profile.
Syntax
remove fcoe-connection
Parameter
ProfileName (required) The name of an existing profile from which the last FCoE connection is being
removed
Example
->remove fcoe-connection MyProfile
Removes an FCoE connection from a profile
Item
Description
set fcoe-connection
Modify an existing FCoE connection.
Syntax
set fcoe-connection
[SpeedType=<1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]
[CustomSpeed=<100Mb-10Gb>] [BootPriority=
[BootPort=
Parameters
ConnectionID
(required)
The ID of an existing FCoE connection. The ID format is
- 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem