Power supply LEDs

Power redundancy is achieved through two independent load-sharing power supplies. In the event of a

power supply failure, or the failure of the power source, the storage system can operate continuously on a

single power supply. Greater redundancy can be achieved by connecting the power supplies to separate

circuits.

AC model

DC model

LED

Description

Definition

1

Input Source Power good

Green — Power is on and input voltage is normal.

Off — Power is off or input voltage is below the minimum

threshold.

2

DC Voltage/Fan Fault/Service Required

Amber — DC output voltage is out of range or a fan is

operating below the minimum required RPM.
Off — DC output voltage is normal.

1

2

1