Hba_ww_id, Hostmode, Hp ssa scripting error messages – HP Scripting Toolkit for Windows 9.50 User Manual
Page 41: Hba_ww_id hostmode
The string can consist of the following:
•
A maximum of 16 characters
•
Embedded space characters but cannot end with a space character
•
Any of the following characters: a–z, A–Z, 0–9, !, @, #, *, (, ), -, _, +, :, ., /, and [space]
HBA_WW_ID
This option specifies which HBA, based on its assigned WWN, is modified by the configuration
changes.
HostMode
This option specifies the HostMode for a selected HBA. Setting the Host Mode optimizes the storage
array for the selected operating system. The available host modes for an HBA are device-specific.
Not all modes are available on all devices. Not all HBAs support a HostMode.
The following operating system options might be available:
•
Default
•
Microsoft Windows
•
OpenVMS
•
Tru64
•
Linux
•
Solaris
•
Netware
•
HP-UX
HP SSA scripting error messages
Comment or clarification
Error message
Error code
The HP SSA process cannot be initiated. You might see this
error message if you are not authenticated to use HP SSA or
if HP SSA is already running.
General error.
1
HP SSA cannot save one or more controller configurations.
Error saving controller.
268
—
Controller is locked by another machine or
user.
278-282
—
Error communicating with controller.
290
An error occurred during the configuration process, but HP
SSA cannot identify the error because there is an internal HP
SSA error.
Internal error.
516
This error message occurs if you attempt to add an odd
number of drives to an array that has RAID 1 logical drives,
and the controller does not support RAID-level migration.
Array requires an odd number of drives.
1052
This error message occurs if a script that is running in
Reconfigure action mode lists fewer physical drives than
Cannot remove physical drives from
existing array.
1053
already exist in the array. HP SSA interprets this script as a
request to remove physical drives from an existing array, but
satisfying this request causes data loss, so HP SSA prevents
the script from running.
HP SSA does not support multiple simultaneous expansions,
migrations, or extensions without saving the configuration
Too many coinciding expansion, migration,
or extension operations.
1065-1066
Using HPSSASCRIPTING
41