Diagnostic tools – HP Integrity rx4640 Server User Manual
Page 45
Diagnosing array problems 45
Item ID Color
Description
2
Green
Auxiliary Power LED. This LED glows steadily when 3.3V
auxiliary voltage is detected. The auxiliary voltage is used
to preserve BBWC data and is available any time that the
system power cords are connected to a power supply.
3
Amber
Battery Health LED. To interpret the illumination patterns of
this LED, see the following table.
4
Green
BBWC Status LED. To interpret the illumination patterns of
this LED, see the following table.
LED3 pattern
LED4 pattern
Interpretation
—
One blink every
two seconds
The system is powered down, and the cache contains data that has
not yet been written to the drives. Restore system power as soon as
possible to prevent data loss.
Data preservation time is extended any time that 3.3 V auxiliary
power is available, as indicated by LED 2. In the absence of
auxiliary power, battery power alone preserves the data. A fully-
charged battery can normally preserve data for at least two days.
The battery lifetime also depends on the cache module size. For
further information, refer to the controller QuickSpecs on the HP
— Double
blink,
then pause
The cache microcontroller is waiting for the host controller to
communicate.
—
One blink per
second
The battery pack is below the minimum charge level and is being
charged. Features that require a battery (such as write cache,
capacity expansion, stripe size migration, and RAID migration) are
temporarily unavailable until charging is complete. The recharge
process takes between 15 minutes and two hours, depending on the
initial capacity of the battery.
—
Steady glow
The battery pack is fully charged, and posted write data is stored in
the cache.
—
Off
The battery pack is fully charged, and there is no posted write data
in the cache.
One blink per
second
One blink per
second
An alternating green and amber blink pattern indicates that the
cache microcontroller is executing from within its boot loader and
receiving new flash code from the host controller.
Steady glow
—
There is a short circuit across the battery terminals or within the
battery pack. BBWC features are disabled until the battery pack is
replaced. The life expectancy of a battery pack is typically more
than three years.
One blink per
second
—
There is an open circuit across the battery terminals or within the
battery pack. BBWC features are disabled until the battery pack is
replaced. The life expectancy of a battery pack is typically more
than three years.
Diagnostic tools
Several diagnostic tools provide feedback about problems with arrays.
- Integrity rx7620 Server Integrity BL860c Server-Blade Integrity rx3600 Server Integrity Superdome sx1000 Server Integrity rx7640 Server Integrity rx8640 Server Integrity rx8620 Server Integrity rx2600 Servers Integrity rx5670 Server Integrity Superdome sx2000 Server Integrity rx1620 Servers Integrity rx2620 Servers Integrity rx6600 Server Integrity rx2660 Servers Integrity BL870c Server-Blade