Diagnosing array problems, Controller board runtime leds – HP Integrity rx4640 Server User Manual
Page 30
Diagnosing array problems 30
Diagnosing array problems
In this section
Controller board runtime LEDs.................................................................................................................. 30
Cache module LEDs................................................................................................................................ 31
Diagnostic tools ..................................................................................................................................... 32
Controller board runtime LEDs
NOTE: During server power-up, each runtime LED illuminates randomly until POST has finished.
LED ID
Color
LED name and interpretation
0
Amber
CR100: Diagnostics Error LED.
1 Amber CR101: Drive Failure LED. A physical drive connected to the controller
has failed.
2 Blue
CR102: SCSI Bus Active LED. At least one of the SCSI buses on the
controller is active.
3
Green
CR103: XOR Active LED. The controller is calculating parity data.
4 Green CR104: Command Outstanding LED. The controller is working on a
command.
5 Blue
CR105: Heartbeat LED. This LED flashes every 2 seconds, unless the
controller is malfunctioning.
6 Green CR106: Gas Pedal LED. This LED, together with item 7, indicates the
amount of controller CPU activity. For details, refer to the following table.
7 Green CR107: Idle Task LED. This LED, together with item 6, indicates the
amount of controller CPU activity. For details, refer to the following table.
- Integrity rx7620 Server Integrity rx5670 Server Integrity rx7640 Server Integrity rx2620 Servers Integrity rx1620 Servers Integrity rx2660 Servers Integrity rx6600 Server Integrity rx2600 Servers Integrity BL860c Server-Blade Integrity rx8620 Server Integrity Superdome sx2000 Server Integrity rx8640 Server Integrity rx3600 Server Integrity Superdome sx1000 Server