Installing management agents – HP Integrity rx4640 Server User Manual
Page 18

Installing device drivers and Management Agents 18
3.
Power up the system. As Linux boots, it recognizes the controller.
4.
Enter one of the following commands as appropriate to ensure that the driver is loaded correctly:
Red Hat:
#mkinitrd -f /boot/efi/efi/redhat/initrd-$(uname -r).img $(uname
-r)
Novell (SLES):
#mkinitrd -k /boot/vmlinux -i/boot/initr
5.
For Novell, enter the following command to confirm that the driver is active:
#lsmod | grep cciss
If the driver is active, the system responds by displaying
cciss
.
Installing Management Agents
The most recent versions of the agents are available on the support page of the HP website
HP Insight Management Agents for Linux on Integrity Servers provided with the agents.
If the new agents do not function correctly, you might also need to update Systems Insight Manager. The
latest version of Systems Insight Manager is available for download at the HP website
- Integrity rx7620 Server Integrity rx5670 Server Integrity rx7640 Server Integrity rx2620 Servers Integrity rx1620 Servers Integrity rx2660 Servers Integrity rx6600 Server Integrity rx2600 Servers Integrity BL860c Server-Blade Integrity rx8620 Server Integrity Superdome sx2000 Server Integrity rx8640 Server Integrity rx3600 Server Integrity Superdome sx1000 Server