beautypg.com

Replacing, moving, or adding hard drives, Identifying the status of a hard drive, Hot-plug scsi hard drive led combinations – HP Integrity rx4640 Server User Manual

Page 22: And consu

background image

Replacing, moving, or adding hard drives 22

Replacing, moving, or adding hard drives

In this section

Identifying the status of a hard drive ......................................................................................................... 22
Recognizing hard drive failure................................................................................................................. 23
Replacing hard drives ............................................................................................................................. 24
Moving drives and arrays ....................................................................................................................... 27
Adding drives ........................................................................................................................................ 28

Identifying the status of a hard drive

When a drive is configured as a part of an array and connected to a powered-up controller, the condition
of the drive can be determined from the illumination pattern of the hard drive status lights (LEDs). The table
("

Hot-plug SCSI hard drive LED combinations

" on page

22

) describes the meanings of the different

illumination patterns.

Hot-plug SCSI hard drive LED combinations

Activity
LED (1)

Online LED
(2)

Fault LED
(3)

Interpretation

On, off, or
flashing

On or off

Flashing

A predictive failure alert has been received for this drive.

Replace the drive as soon as possible.

On, off, or
flashing

On

Off

The drive is online and is configured as part of an array.

If the array is configured for fault tolerance and all other drives in the
array are online, and a predictive failure alert is received or a drive
capacity upgrade is in progress, you may replace the drive online.