28 Turn-On Checkout
Power Module Turn-On State
When you turn on the mainframe, the power module goes through a self-test. All front panel readout digits and
annunciators turn on briefly. The panel then remains in the state shown in Table 3-1A.
Note
The figure assumes the power module still retains its factory default turn-on state. You can change this
state if desired (see "Chapter 4 - Basic Power Module Commands").
Checking Basic Module Functions
The power module is designed for remote programming over the GPIB. It also can be locally programmed from the
optional Agilent 66001A MPS Keyboard. Table 3-2 gives the SCPI commands for the remotely programmed tests. You
can send these same commands from the keyboard (see "Appendix B").
Table 3-2. Testing Basic Functions with SCPI Commands
Command
Action
Display Response
VOLTS
AMPS
CV
CC
Addr*
Dis
Prot
Output Voltage (Disconnect Load)
VOLT 5.1
Set output voltage to 5.1 V
0.00
0.00
Off
Off
On
On
Off
OUTP ON
Enable the output
5. 10
0.00
On
Off
On
Off
Off
Overvoltage Protection
VOLT:PROT 4.9
Activate OVP circuit (by
setting protection voltage
0.00
0.00
Off
Off
On
Off
On
below output voltage)
VOLT:PROT MAX
Clear OVP circuit
5. 10
0.00
Off
Off
On
Off
Off
OUTP:PROT:CLE
Clear OVP circuit
5. 10
0.00
On
Off
On
Off
Off
Save and Recall Functions
*SAV 5
Save present state to
location 5
5.10
0.00
On
Off
On
Off
Off
VOLT 3.55
Set output voltage to 3.55 V
3.55
0.00
On
Off
On
Off
Off
OUTP OFF
Turn off the output
0.00
0.00
Off
Off
On
On
Off
*SAV 6
Save present state to
location 6
0.00
0.00
Off
Off
On
On
Off
*RCL 5
Restore state 5
5.10
0.00
On
Off
On
Off
Off
*RCL 6
Restore state 6
0.00
0.00
Off
Off
On
On
Off
Output Current (With output disabled, short the
output terminals with a wire size sufficient to carry
the maximum current of the module.)
CURR 3.1
Set output current to 3.1
amps
0.00
0.00
Off
Off
On
On
Off
OUTP ON
Enable the output
0.00
3.10
Off
On
On
Off
Off
Overcurrent Protection
CURR:PROT:STAT
ON
Activate OCP circuit (by
enabling OCP when the
output is shorted)
0.00
0.00
Off
Off
On
Off
On
CURR:PROT:STAT
OFF
Clear OCP circuit
0.00
0.00
Off
On
On
On
Off
OUTP:PROT:CLE
Clear OCP circuit
0.00
3.10
Off
On
On
Off
Off
*Addr will not light if the module is controlled from the keyboard.