Agilent Technologies 66001A User Manual
Page 13
![background image](/manuals/39250/13/background.png)
General Information 13
Table 1-2. Supplemental Characteristics (continued)
Agilent Model
Parameter
66101A
66102A
66103A
66104A
66105A
66106A
Temperature Coefficients (change in
output per
°
C after a 30-minute
warmup)
Output Voltage:
30 ppm +
0.1 mV
0.2 mV
0.3 mV
0.6 mV
1.1 mV
1.8 mV
Output Current:
30 ppm +
0.2 mA
0.1 mA
0.05 mA
0.03 mA
0.01 mA
0.006 mA
Voltage Readback:
20 ppm +
0.1 mV
0.2 mV
0.2 mV
0.7 mV
0.7 mV
1.1 mV
±
Current Readback:
20 ppm +
0.2 mA
0.1 mA
0.05 mA
0.02 mA
0.02 mA
0.02 mA
OV Protection:
1 mV
2 mV
4 mV
8 mV
16 mV
30 mV
Maximum Reverse Current
(maximum current, without damage,
that the power module will withstand
while turned on and with the dc output
reverse biased by an external dc
source):
16 A
7.5 A
4.5 A
2.5 A
1.25 A
0.75 A
Typical Output Common Mode Noise
Current*
rms:
0.5 mA
peak-peak:
5 mA
* Referenced to mainframe chassis ground.
Remote Sensing Capability
Voltage drop per lead:
Up to 1/2 of rated output voltage
Load voltage:
Subtract voltage drop in load leads from specified output voltage rating
Load Regulation:
For each 1-volt change in the negative output lead due to load current change,
add 2 mV to the voltage load regulation specification (see Table 1-1).
Command Processing Time (average
time for output to begin to change after
receipt of digital data when the power
module is connected directly to the
GPIB):
20 ms
Output Voltage Programming
Response Time*
Time for output to change from 10% to
90% of its total excursion:
< 20 ms
Time for output to change from 90% to
10% of its total excursion:
< 20 ms
< 50 ms
Time for output voltage to settle to
within 0.1% of the final value:
120 ms