beautypg.com

AMD Athlon 27493 User Manual

Page 25

background image

Chapter 4

Power Management

13

26237C—May 2003

AMD Athlon™ XP Processor Model 10 Data Sheet

Preliminary Information

The Northbridge contains BIOS programmable registers to
enable the system bus disconnect in response to Halt and Stop
Grant special cycles. When the Northbridge receives the Halt or
Stop Grant special cycle from the processor and, if there are no
outstanding probes or data movements, the Northbridge
deasserts CONNECT a minimum of eight SYSCLK periods after
the last command sent to the processor. The processor detects
the deassertion of CONNECT on a rising edge of SYSCLK and
deasserts PROCRDY to the Northbridge. In return, the
N o r t h b r i d g e a s s e r t s C L K F W D R S T i n a n t i c i p a t i o n o f
reestablishing a connection at some later point.

Note: The Northbridge must disconnect the processor from the

AMD Athlon system bus before issuing the Stop Grant
special cycle to the PCI bus or passing the Stop Grant special
cycle to the Southbridge for systems that connect to the
Southbridge with HyperTransport™ technology.

This note applies to current chipset implementation—
alternate chipset implementations that do not require this
are possible.

Note: In response to Halt special cycles, the Northbridge passes the

Halt special cycle to the PCI bus or Southbridge
immediately.

The processor can receive an interrupt after it sends a Halt
special cycle, or STPCLK# deassertion after it sends a Stop
Grant special cycle to the Northbridge but before the
disconnect actually occurs. In this case, the processor sends the
Connect special cycle to the Northbridge, rather than
continuing with the disconnect sequence. In response to the
Connect special cycle, the Northbridge cancels the disconnect
request.

The system is required to assert the CONNECT signal before
returning the C-bit for the connect special cycle (assuming
CONNECT has been deasserted).

For more information, see the AMD Athlon™ and AMD Duron™
System Bus Specification
, order# 21902 for the definition of the
C-bit and the Connect special cycle.