11

CLEANING, SANITIZING, AND CARTRIDGE REPLACEMENT PROCEDURE (cont.)

19. CAUTION: Do not remove protective plastic bag from

replacement filter/membrane cartridges until

instructed.

Install "O" rings into filter housings. Open top of filter
bag enough to expose filter cap and "O" ring grooves.
Place a small amount of "O" ring lubricant on surface
of each "O" ring.


20. CAUTION: Tighten filter housings by hand only. Do

not use tools as they will over-tighten and damage

housings. Take care not to cut or pinch o-rings.

CAUTION: Refer to Page 8, Figure 8.B. for

location of each cartridge.

Install filter and membrane cartridges. Hold cartridge
by its protective plastic bag and insert cartridge into
manifold turning it 1/4 turn as it enters the port. Slide
bag from cartridge and discard. Replace each filter
housing as each cartridge is installed.


21. Turn feed water valve slowly to open position.

22. Confirm system is producing water. Unit will be

sending rinse water to drain.


Smartap® Water Quality Monitor

TO REPLACE BATTERY: Perform Steps 23 – 29

NOTE: Replace battery with a new alkaline 9-volt battery.

23. CAUTION: Wiring within module cover connects

monitor components. If wires, circuit board, or
connections are damaged and/or wetted, monitor will

not function.

Remove module cover by gently lifting manifold cover
up and away from manifold body.


24. Disconnect battery. The battery connection is a snap

type connector (Figure 9).


25. Remove battery by sliding it out of its holder.

26. Slide new battery into its holder.

27. CAUTION: Verify battery connector alignment

before making connection (Figure 9).

Connect battery by pressing clip onto battery
terminals.

NOTE:

Release button immediately after light

illuminates. Test is to confirm battery connection,
not water quality.


28. Test battery connection by activating monitor. Press

push button. If an indicator light illuminates,
connection is good.


29. Replace manifold cover by gently pushing manifold

cover onto manifold until it snaps into place.


30. Open product water faucet. Let water flow until all

air has been expelled from the system.


31. Close product water faucet. Wait 30 minutes, check

connections for leaks, and correct if necessary.


Icemaker/Extra point of use: Check lines for leaks.


32. Allow storage tank to fill overnight.

33. WARNING: DO NOT USE THE FIRST FULL

STORAGE TANK OF WATER

Discard (to drain) first full tank of water by opening
product water faucet until water flow stops, then
close faucet. This flushes sanitizing solution from

system.

Icemaker: Let tray/bin fill with ice cubes. Discard all
ice cubes to drain. This flushes sanitizing solution
from lines to icemaker. Replace delivery device filter
(if applicable).


34. System is ready to use. Should there be any after

taste or odor, drain storage tank and repeat Steps 32
and 33.

Figure 9: Smartap

®

Battery Connections

DO NOT USE THE FIRST

FULL STORAGE TANK OF WATER

Allow reservoir to fill overnight.

Dispense this water to drain.

This process removes sanitizing solution from system,

sanitizes fittings and tubing, and sends solution to drain.